{
    "help": "Return the metadata of a dataset (package) and its resources. :param id: the id or name of the dataset :type id: string",
    "success": true,
    "result": {
        "id": "b2722fbc-7f1b-422a-9ced-b586eefc162b",
        "url": "https://www.inptdat.de/node/672",
        "source": {
            "name": "CCP",
            "application": "basic research",
            "specification": "AC, high frequency, low pressure, non-thermal",
            "properties": "<p>An asymmetric capacitively coupled radio frequency discharge was investigated. The planar RF electrode was made of stainless steel and had a diameter of 120 mm. It was powered at 13.56 MHz by an RF generator (Advanced Energy, Cesar 133) and an automatic matching network (Advanced Energy, Navio). The RF electrode was positioned at a distance of 55 mm beneath the top surface of the grounded reactor vessel, which consisted of aluminum and was cylindrically shaped, with a diameter of 240 mm and a height of 105 mm. The applied RF power was varied between 20 and 100 W.</p>\n",
            "procedure": "<p>Before filling the reactor vessel with oxygen gas, it was pumped to a base pressure of p&lt;5E-4 mbar by a turbopump system (Pfeiffer Balzers, TSU 062). After that, oxygen was admitted to the vessel and the pressure was adjusted to 0.7 or 1.3 mbar, respectively.</p>\n"
        },
        "medium": {
            "name": "O2",
            "properties": "<p>Pure O2 was used as a working gas, at a pressure of 0.7 or 1.3 mbar, and a flow rate of 70 sccm. The gas flow was set to 70 sccm by a mass flow controller (MFC) (MKS 1179A with control unit MKS 647C) connected to an oxygen gas cylinder (Air Liquide, gas purity 99.998%).</p>\n"
        },
        "target": [],
        "diagnostics": {
            "name": "THz absorption spectroscopy",
            "procedure": "<p>Absolute densities of ground-state atomic oxygen were measured with THz absorption spectroscopy, using the fine structure transition of atomic oxygen at 4.74477749 THz (i.e. 158.268741 cm-1). A tunable THz QCL in continuous-wave mode was used as the radiation source. The THz QCL was operated in a Stirling cryocooler (Ricor K535) at a temperature of either 44.30 or 54.45 K. The laser temperature was regulated by an additional temperature controller (Stanford Research Systems, CTC100), which was capable of a temperature control with &lt;5 mK stability. Tuning of the laser frequency was achieved by linearly ramping the input current. The current was supplied by a laser driver (Wavelength Electronics, QCL1000 OEM) that was controlled by a function generator (Tektronix, AFG3022C) to provide sawtooth waveforms with a frequency of 10 Hz. A phase-locked optical chopper (New Focus, Model 3502) with a frequency of 5 Hz was used to block each second period of the laser output. The generated THz radiation was collected by a gold-coated parabolic mirror to produce a collimated beam with a diameter of approximately 3 mm. A window made of silicon allowed for the laser beam to pass through the plasma reactor, at a height of approximately 18 mm above the RF electrode. A gold-coated mirror at the back end of the reactor reflected the laser beam back towards the entrance window. The effective absorption length was estimated to be 84 cm (i.e. the total length of the laser beam path within the plasma reactor). After passing through the plasma reactor, the laser radiation was detected by a helium-cooled bolometer (Infrared Laboratories, 4.2K Bolometer). The detected signals were recorded with a digital sampling oscilloscope (R&amp;S, RTO 1014).</p>\n"
        },
        "resource": [
            {
                "id": "15a4c673-edf0-42de-bed2-43de8d7cd911",
                "url": "https://www.inptdat.de/system/files/node672_figure2.csv",
                "filetype": "csv",
                "datatype": "data table",
                "range": "Wavenumber: 158.19-158.33 cm-1",
                "quality": "published"
            },
            {
                "id": "08f45edc-72ea-4e6c-b442-01ff1bb076a3",
                "url": "https://www.inptdat.de/system/files/node672_figure3.csv",
                "filetype": "csv",
                "datatype": "data table",
                "range": "Wavenumber: 158.215-158.352 cm-1",
                "quality": "published"
            },
            {
                "id": "5b755e26-5a63-4e1b-94df-3698e3e979ad",
                "url": "https://www.inptdat.de/system/files/node672_figure4.csv",
                "filetype": "csv",
                "datatype": "data table",
                "range": "Relative wavenumber: -0.0025-0.0015 cm-1",
                "quality": "published"
            },
            {
                "id": "794d9922-dceb-4b45-a5fb-c8ac302f5f08",
                "url": "https://www.inptdat.de/system/files/node672_figure5.csv",
                "filetype": "csv",
                "datatype": "data table",
                "range": "Wavenumber: 158.213-158.216 cm-1",
                "quality": "published"
            },
            {
                "id": "dae3ba5c-bbbe-4378-8512-4b3c244ae5c5",
                "url": "https://www.inptdat.de/system/files/node672_figure6.csv",
                "filetype": "csv",
                "datatype": "data table",
                "range": "Wavenumber: 158.253-158.262 cm-1",
                "quality": "published"
            },
            {
                "id": "64aca155-8660-423e-9302-e56db7bf84c3",
                "url": "https://www.inptdat.de/system/files/node672_figure7.csv",
                "filetype": "csv",
                "datatype": "data table",
                "range": "Wavenumber: 158.267-158.270 cm-1",
                "quality": "published"
            },
            {
                "id": "cdc276db-ac8f-44ac-bdbf-8c25fb1bd504",
                "url": "https://www.inptdat.de/system/files/node672_figure8.csv",
                "filetype": "csv",
                "datatype": "data table",
                "range": "Applied RF power: 20-100 W",
                "quality": "published"
            }
        ]
    }
}