{"@context":"https://project-open-data.cio.gov/v1.1/schema/catalog.jsonld","@id":"https://www.inptdat.de/data.json","@type":"dcat:Catalog","conformsTo":"https://project-open-data.cio.gov/v1.1/schema","describedBy":"https://project-open-data.cio.gov/v1.1/schema/catalog.json","dataset":[{"@type":"dcat:Dataset","accessLevel":"public","contactPoint":{"fn":"Marion Henkel","hasEmail":"mailto:marion.henkel@inp-greifswald.de"},"description":"Double-pulse laser induced breakdown spectroscopy (LIBS) measurements in water with up to 600 bar hydrostatic pressure and 150 mJ energy of each pulse were done to select a setup which promote separated spectral lines in the observed plasma emission even at elevated pressures, where line broadening until loss of the most spectral information can occur. For this a compact spectrometer und a Czerny-Turner spectrometer, both fiber-based, has been applied to investigate the dependence of the emitted radiation on different parameters and hydrostatic pressure. The spectral data with an exposure time of 100 ns was measured with a Roper Acton Spectra Pro 500i with connected PI-MAX2 camera, whereas the spectral data with an exposure time of 1 ms was measured with an Avantes AvaSpec ULS17502F-USB2 compact spectrometer.","distribution":[{"@type":"dcat:Distribution","downloadURL":"https://www.inptdat.de/dataset/39d85ef6-38c4-4952-9ff1-2d8689ad7dc2/resource/0b11bd72-ce38-4542-80d3-57aea104df2a/download/node815_calibration.zip","mediaType":"application/zip","format":"ZIP","description":"Calibration files","title":"Double-pulse LIBS in water - calibration"},{"@type":"dcat:Distribution","downloadURL":"https://www.inptdat.de/dataset/39d85ef6-38c4-4952-9ff1-2d8689ad7dc2/resource/01bf13b0-22e1-403a-aa72-ba59c2bfe6e1/download/node815_avantes-spectrometer_hydrostatic-pressure.zip","mediaType":"application/zip","format":"ZIP","description":"Spectra measured with the Avantes spectrometer for different hydrostatic pressures (see metdata file).","title":"Double-pulse LIBS in water - Avantes (hydrostatic pressure)"},{"@type":"dcat:Distribution","downloadURL":"https://www.inptdat.de/dataset/39d85ef6-38c4-4952-9ff1-2d8689ad7dc2/resource/dbcf58f8-0bb1-4d22-88c2-0bcbc157d679/download/node815_avantes-spectrometer_laser-pulse-energy.zip","mediaType":"application/zip","format":"ZIP","description":"Spectra measured with the Avantes spectrometer for different laser pulse energies (see metdata file).","title":"Double-pulse LIBS in water - Avantes (laser pulse energy)"},{"@type":"dcat:Distribution","downloadURL":"https://www.inptdat.de/dataset/39d85ef6-38c4-4952-9ff1-2d8689ad7dc2/resource/a7ac3c7f-9918-4692-8c2f-521971d8a9ec/download/node815_czerny-turner-spectrometer_time-evolution.zip","mediaType":"application/zip","format":"ZIP","description":"Time evolution of spectra measured with the Czerny-Turner spectrometer (see metdata file).","title":"Double-pulse LIBS in water - Czerny-Turner (time evolution)"},{"@type":"dcat:Distribution","downloadURL":"https://www.inptdat.de/dataset/39d85ef6-38c4-4952-9ff1-2d8689ad7dc2/resource/ae898f46-42c2-4906-b25b-8c2a823621f6/download/node815_spectrometer-metadata.xml","mediaType":"application/xml","format":"openxml","description":"Metadata of all raw data files contained in the zip archives.","title":"Double-pulse LIBS in water - resource metadata"}],"identifier":"39d85ef6-38c4-4952-9ff1-2d8689ad7dc2","issued":"2024-02-06","keyword":["Laser-induced plasma","plasma in liquids"],"landingPage":"https://www.inptdat.de/dataset/double-pulse-libs-water-600-bar-hydrostatic-pressure-and-150-mj-energy-each-pulse","language":["en"],"license":"https://creativecommons.org/licenses/by/4.0/","modified":"2024-03-05","publisher":{"@type":"org:Organization","name":"INP, LZH"},"theme":["Materials / Surfaces","Plasma Chemical Processes","Plasma in Liquids","Thermal Plasma Technology"],"title":"Double-pulse LIBS in water with up to 600 bar hydrostatic pressure and up to 150 mJ energy of each pulse","references":["https://doi.org/10.1016/j.sab.2024.106877"]}]}