{"@context":"https://project-open-data.cio.gov/v1.1/schema/catalog.jsonld","@id":"https://www.inptdat.de/data.json","@type":"dcat:Catalog","conformsTo":"https://project-open-data.cio.gov/v1.1/schema","describedBy":"https://project-open-data.cio.gov/v1.1/schema/catalog.json","dataset":[{"@type":"dcat:Dataset","accessLevel":"public","contactPoint":{"fn":"Baeva, Margarita","hasEmail":"mailto:baeva@inp-greifswald.de"},"description":"The dataset provides the data related to the modelling of microdischarges in metal vapour of cadmium. Such microdischarges occur in a testing equipment for the safety assessment of electric devices for explosion protection. A one-dimensional unified non-equilibrium model that resolves the entire discharge gap is employed and simulations are conducted for a constant current of 60mA with gap lengths varying between 20 μm and 160 μm. These conditions match the experiment and enable a comparison with measured data. The predicted discharge voltage obtained as a function of the discharge length is compared to the measurements and shows a good agreement. The model provides the heat generation relevant to the prediction of a gas mixture ignition.","distribution":[{"@type":"dcat:Distribution","downloadURL":"https://www.inptdat.de/dataset/154919d7-75ef-4b51-a86a-0c653b06fb79/resource/42032958-ec17-47b6-921d-f545ac6ed887/download/node943_figure2.csv","mediaType":"text/csv","format":"CSV","description":"Rate coefficients of direct Kid, step-wise Kis, and total ionisation Ktot of Cd atoms, and 3-body recombination Krec as a function of the electron temperature Te.","title":"Modelling microdischarges in metal vapour of cadmium in comparison with electrical measurements - Rate coefficients as a function of the electron temperature (figure 2)"},{"@type":"dcat:Distribution","downloadURL":"https://www.inptdat.de/dataset/154919d7-75ef-4b51-a86a-0c653b06fb79/resource/03f66362-19ff-4300-9aaa-b797fa8a3f32/download/node943_figure3.csv","mediaType":"text/csv","format":"CSV","description":"Current density of emitted electrons due to thermo-field emission as a function of the electric field for various temperatures at the cathode surface.","title":"TModelling microdischarges in metal vapour of cadmium in comparison with electrical measurements - Thermo-field emission current density of emitted electrons (figure 3)"},{"@type":"dcat:Distribution","downloadURL":"https://www.inptdat.de/dataset/154919d7-75ef-4b51-a86a-0c653b06fb79/resource/8284e8a8-21d3-4a77-aec0-6e2debf87c89/download/node943_figure4_1.csv","mediaType":"text/csv","format":"CSV","description":"Measured voltage as a function of the discharge length.","title":"Modelling microdischarges in metal vapour of cadmium in comparison with electrical measurements - Measured voltage as a function of the discharge length (figure 4)"},{"@type":"dcat:Distribution","downloadURL":"https://www.inptdat.de/dataset/154919d7-75ef-4b51-a86a-0c653b06fb79/resource/6da9197c-edb2-4344-b7f4-31d8e2bf01e9/download/node943_figure4_2.csv","mediaType":"text/csv","format":"CSV","description":"Discharge voltage for discharge lengths of 60, 100, and 160 µm and values of the field enhancement factor (FEF) of 130, 140, 150, and 160.","title":"Modelling microdischarges in metal vapour of cadmium in comparison with electrical measurements - Computed discharge voltage (figure 4)"},{"@type":"dcat:Distribution","downloadURL":"https://www.inptdat.de/dataset/154919d7-75ef-4b51-a86a-0c653b06fb79/resource/c922367d-a2de-4453-b21d-69df715ad4e6/download/node943_figure5.csv","mediaType":"text/csv","format":"CSV","description":"Calculated number density of electrons and Cd+ ions for selected gap lengths during the contact opening. The fiel enhancement factor is 140.","title":"Modelling microdischarges in metal vapour of cadmium in comparison with electrical measurements - Number density of electrons and Cd+ ions during the contact opening (figure 5)"},{"@type":"dcat:Distribution","downloadURL":"https://www.inptdat.de/dataset/154919d7-75ef-4b51-a86a-0c653b06fb79/resource/1ac1d195-f4a7-4050-b941-46988511f684/download/node943_figure6.csv","mediaType":"text/csv","format":"CSV","description":"Distribution of the electric potential and electric field  in the discharge gap  for selected gap lengths during the contact opening. Field enhancement factor 140.","title":"Modelling microdischarges in metal vapour of cadmium in comparison with electrical measurements - Calculated electric potential and electric field in the discharge gap during the contact opening (figure 6)"},{"@type":"dcat:Distribution","downloadURL":"https://www.inptdat.de/dataset/154919d7-75ef-4b51-a86a-0c653b06fb79/resource/e6cd14a6-5173-451e-9626-4817a7b9e055/download/node943_figure7.csv","mediaType":"text/csv","format":"CSV","description":"Spatial distributions of the gas (T) and electron (Te) temperatures in the discharge gap for selected gap lengths during the contact opening. Field enhancement factor 140.","title":"Modelling microdischarges in metal vapour of cadmium in comparison with electrical measurements - Computed distributions of the gas and electron temperatures in the discharge gap during the contact opening (figure 7)"}],"identifier":"154919d7-75ef-4b51-a86a-0c653b06fb79","issued":"2025-09-11","keyword":["cadmium","fluid model","microdischarge"],"landingPage":"https://www.inptdat.de/dataset/modelling-microdischarges-metal-vapour-cadmium-comparison-electrical-measurements-dataset","language":["en"],"license":"https://creativecommons.org/licenses/by/4.0/","modified":"2026-05-27","publisher":{"@type":"org:Organization","name":"INP, PTB Braunschweig"},"theme":["Thermal Plasma Technology"],"title":"Modelling microdischarges in metal vapour of cadmium in comparison with electrical measurements - Dataset","references":["https://doi.org/10.14311/ppt.2025.2.112"]}]}