<?xml version="1.0"?>
<rdf:RDF xmlns:foaf="http://xmlns.com/foaf/0.1/" xmlns:owl="http://www.w3.org/2002/07/owl#" xmlns:rdfs="http://www.w3.org/2000/01/rdf-schema#" xmlns:rdf="http://www.w3.org/1999/02/22-rdf-syntax-ns#" xmlns:dcat="http://www.w3.org/ns/dcat#" xmlns:dct="http://purl.org/dc/terms/" xmlns:adms="http://www.w3.org/ns/adms#" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:time="http://www.w3.org/2006/time#" xmlns:dcterms="http://purl.org/dc/terms/" xmlns:vcard="http://www.w3.org/2006/vcard/ns#"><dcat:Dataset rdf:about="https://www.inptdat.de/dataset/modelling-studies-arcs-short-length-between-copper-electrodes-dataset"><dct:title>Modelling studies of arcs of short length between copper electrodes: Dataset</dct:title><dct:description><![CDATA[<p>The data correspond to the results of modelling studies of DC electric arcs at a current of 2 A in air with admixture of copper metal vapour. Experimental findings are used to adjust input parametrs of the model in order to achieve a good match. The simulations are performed strating with a discharge burning with a minimum gap length of 30 µm for a physical time of 11 ms. Then, the separation of the electrodes is followed for further 51 ms and the discharge gap is increased up to 3 mm. The comparision of experimental and modelling data is based on the measured arc voltage. Variations of the discharge radius during the contact opening, the field enhancement factor, and the molar fraction of copper metal vaopur show the sensitivity of the computed arc voltage.</p>
]]></dct:description><dcat:keyword>air</dcat:keyword><dcat:keyword>copper metal vapour</dcat:keyword><dcat:keyword>electric arcs</dcat:keyword><dcat:keyword>non-equilibrium plasma</dcat:keyword><dcat:theme>Thermal Plasma Technology</dcat:theme><dct:identifier>92c2e1d1-e75b-4c53-ada1-70c2e496dfad</dct:identifier><dct:issued>2025-08-26T00:00:00+02:00</dct:issued><dct:modified>2025-09-12T10:21:17+02:00</dct:modified><dct:language>en</dct:language><dct:publisher>INP, IEE</dct:publisher><dcat:distribution rdf:resource="https://www.inptdat.de/dataset/modelling-studies-arcs-short-length-between-copper-electrodes-dataset/resource/6d5b89c8-49dd"/><dcat:distribution rdf:resource="https://www.inptdat.de/dataset/modelling-studies-arcs-short-length-between-copper-electrodes-dataset/resource/139fd88d-fcf5"/><dcat:distribution rdf:resource="https://www.inptdat.de/dataset/modelling-studies-arcs-short-length-between-copper-electrodes-dataset/resource/f207f08d-4d36"/><dcat:distribution rdf:resource="https://www.inptdat.de/dataset/modelling-studies-arcs-short-length-between-copper-electrodes-dataset/resource/f5495c63-ebf8"/><dcat:distribution rdf:resource="https://www.inptdat.de/dataset/modelling-studies-arcs-short-length-between-copper-electrodes-dataset/resource/4c8758c8-d4e9"/><dcat:distribution rdf:resource="https://www.inptdat.de/dataset/modelling-studies-arcs-short-length-between-copper-electrodes-dataset/resource/767ce870-0892"/><dcat:distribution rdf:resource="https://www.inptdat.de/dataset/modelling-studies-arcs-short-length-between-copper-electrodes-dataset/resource/6f803e36-3f64"/><dcat:distribution rdf:resource="https://www.inptdat.de/dataset/modelling-studies-arcs-short-length-between-copper-electrodes-dataset/resource/1c6871aa-5472"/></dcat:Dataset><dcat:Distribution rdf:about="https://www.inptdat.de/dataset/modelling-studies-arcs-short-length-between-copper-electrodes-dataset/resource/6d5b89c8-49dd"><dct:title>Modelling studies of arcs of short length between copper electrodes - Computed arc voltage as a function of the time of moving for various discharge radii (figure 1)</dct:title><dct:description><![CDATA[<p>Computed arc voltage as a function of the time of moving for a field enhancement factor of 140 and a molar fraction of Cu 0.002.</p>
]]></dct:description><dct:issued>2025-07-15T10:34:05+02:00</dct:issued><dct:modified>2025-08-26T13:47:34+02:00</dct:modified><dcat:accessURL rdf:resource=""/><dcat:downloadURL rdf:resource="https://www.inptdat.de/system/files/node942_figure1_0.csv"/><dcat:mediaType>text/csv</dcat:mediaType><dct:format>csv</dct:format><dcat:byteSize>480</dcat:byteSize><foaf:page>https://www.inptdat.de/dataset/modelling-studies-arcs-short-length-between-copper-electrodes-dataset/resource/6d5b89c8-49dd</foaf:page></dcat:Distribution><dcat:Distribution rdf:about="https://www.inptdat.de/dataset/modelling-studies-arcs-short-length-between-copper-electrodes-dataset/resource/139fd88d-fcf5"><dct:title>Modelling studies of arcs of short length between copper electrodes - Computed arc voltage as a function of the time of moving for various values of the field enhancement factor (figure 2)</dct:title><dct:description><![CDATA[<p>The simulation are performed with a molar fraction of copper of 0.002 and a discharge radius factor of 1.2.</p>
]]></dct:description><dct:issued>2025-07-15T10:39:00+02:00</dct:issued><dct:modified>2025-08-26T13:47:34+02:00</dct:modified><dcat:accessURL rdf:resource=""/><dcat:downloadURL rdf:resource="https://www.inptdat.de/system/files/node942_figure2_0.csv"/><dcat:mediaType>text/csv</dcat:mediaType><dct:format>csv</dct:format><dcat:byteSize>582</dcat:byteSize><foaf:page>https://www.inptdat.de/dataset/modelling-studies-arcs-short-length-between-copper-electrodes-dataset/resource/139fd88d-fcf5</foaf:page></dcat:Distribution><dcat:Distribution rdf:about="https://www.inptdat.de/dataset/modelling-studies-arcs-short-length-between-copper-electrodes-dataset/resource/f207f08d-4d36"><dct:title>Modelling studies of arcs of short length between copper electrodes - Computed arc voltage as a function of the time of moving for various admixtures of copper metal vapour (figure 3)</dct:title><dct:description><![CDATA[<p>The molar fraction of copper metal vapour has values of 0.002, 0.005, and 0.01. The simulations are performed with a field enhamcement factor of 140 and a discharge radius factor of 1.2.</p>
]]></dct:description><dct:issued>2025-07-15T11:18:12+02:00</dct:issued><dct:modified>2025-08-26T13:47:34+02:00</dct:modified><dcat:accessURL rdf:resource=""/><dcat:downloadURL rdf:resource="https://www.inptdat.de/system/files/node942_figure3.csv"/><dcat:mediaType>text/csv</dcat:mediaType><dct:format>csv</dct:format><dcat:byteSize>392</dcat:byteSize><foaf:page>https://www.inptdat.de/dataset/modelling-studies-arcs-short-length-between-copper-electrodes-dataset/resource/f207f08d-4d36</foaf:page></dcat:Distribution><dcat:Distribution rdf:about="https://www.inptdat.de/dataset/modelling-studies-arcs-short-length-between-copper-electrodes-dataset/resource/f5495c63-ebf8"><dct:title>Modelling studies of arcs of short length between copper electrodes - Distribution of the electric potential for selected gap lengths during the contact opening (figure 4a)</dct:title><dct:description><![CDATA[<p>The computed electric potential is shown for a number of gap lengths during the contact opening. The simulation is performed with a field enhancement factor of 140 and a discharge radius factor of 1.2.</p>
]]></dct:description><dct:issued>2025-07-15T11:37:15+02:00</dct:issued><dct:modified>2025-08-26T13:47:34+02:00</dct:modified><dcat:accessURL rdf:resource=""/><dcat:downloadURL rdf:resource="https://www.inptdat.de/system/files/node942_figure4a_0.csv"/><dcat:mediaType>text/csv</dcat:mediaType><dct:format>csv</dct:format><dcat:byteSize>656749</dcat:byteSize><foaf:page>https://www.inptdat.de/dataset/modelling-studies-arcs-short-length-between-copper-electrodes-dataset/resource/f5495c63-ebf8</foaf:page></dcat:Distribution><dcat:Distribution rdf:about="https://www.inptdat.de/dataset/modelling-studies-arcs-short-length-between-copper-electrodes-dataset/resource/4c8758c8-d4e9"><dct:title>Modelling studies of arcs of short length between copper electrodes - Distribution of the electron temperature in the discharge gap for various gap lengths during the contact separation (figure 4b1)</dct:title><dct:description><![CDATA[<p>The data shows the distribution of the electron temperature in the discharge gap for various gap lengths during the contact separation. The distance to the cathode corresponds to the respective gap lengths, i.e. it varies up to 30µm, 300µm, 600µm, 90µm, 1.2mm, 1.5mm, 1.8.mm, 2.1mm, 2.4mm, 2.7mm, and 3mm.<br />
Distance zero correspond to the position of the cathode.</p>
]]></dct:description><dct:issued>2025-07-15T15:02:41+02:00</dct:issued><dct:modified>2025-08-26T13:47:34+02:00</dct:modified><dcat:accessURL rdf:resource=""/><dcat:downloadURL rdf:resource="https://www.inptdat.de/system/files/node942_figure4b_1.csv"/><dcat:mediaType>text/csv</dcat:mediaType><dct:format>csv</dct:format><dcat:byteSize>662136</dcat:byteSize><foaf:page>https://www.inptdat.de/dataset/modelling-studies-arcs-short-length-between-copper-electrodes-dataset/resource/4c8758c8-d4e9</foaf:page></dcat:Distribution><dcat:Distribution rdf:about="https://www.inptdat.de/dataset/modelling-studies-arcs-short-length-between-copper-electrodes-dataset/resource/767ce870-0892"><dct:title>Modelling studies of arcs of short length between copper electrodes - Distribution of the gas temperature in the discharge gap for various gap lengths during the contact separation (figure4b2)</dct:title><dct:description><![CDATA[<p>The data shows the distribution of the gas temperature in the discharge gap for various gap lengths during the contact separation. The distance to the cathode corresponds to the respective gap lengths, i.e. it varies up to 30µm, 300µm, 600µm, 90µm, 1.2mm, 1.5mm, 1.8.mm, 2.1mm, 2.4mm, 2.7mm, and 3mm.<br />
Distance zero correspond to the position of the cathode.</p>
]]></dct:description><dct:issued>2025-07-15T15:09:10+02:00</dct:issued><dct:modified>2025-08-26T13:47:34+02:00</dct:modified><dcat:accessURL rdf:resource=""/><dcat:downloadURL rdf:resource="https://www.inptdat.de/system/files/node942_figure4b_2.csv"/><dcat:mediaType>text/csv</dcat:mediaType><dct:format>csv</dct:format><dcat:byteSize>662828</dcat:byteSize><foaf:page>https://www.inptdat.de/dataset/modelling-studies-arcs-short-length-between-copper-electrodes-dataset/resource/767ce870-0892</foaf:page></dcat:Distribution><dcat:Distribution rdf:about="https://www.inptdat.de/dataset/modelling-studies-arcs-short-length-between-copper-electrodes-dataset/resource/6f803e36-3f64"><dct:title>Modelling studies of arcs of short length between copper electrodes - Distribution of the mole fraction of neutral species in the discharge gap for a gap length of 3 mm (figure 5a)</dct:title><dct:description><![CDATA[<p>The figure shows the distribution of the molar fractions of the neutral species in the air-Cu plasma for a gap length of  3mm (fully opened contacts). the simulation is performed for a field enhancement factor of 140, a discharge radius factor of 1.2, and an initial molar fraction of Cu atoms of 0.002.<br />
Distance zero correspond to the position of the cathode.</p>
]]></dct:description><dct:issued>2025-07-15T15:22:34+02:00</dct:issued><dct:modified>2025-08-26T13:47:34+02:00</dct:modified><dcat:accessURL rdf:resource=""/><dcat:downloadURL rdf:resource="https://www.inptdat.de/system/files/node942_figure5a.csv"/><dcat:mediaType>text/csv</dcat:mediaType><dct:format>csv</dct:format><dcat:byteSize>428704</dcat:byteSize><foaf:page>https://www.inptdat.de/dataset/modelling-studies-arcs-short-length-between-copper-electrodes-dataset/resource/6f803e36-3f64</foaf:page></dcat:Distribution><dcat:Distribution rdf:about="https://www.inptdat.de/dataset/modelling-studies-arcs-short-length-between-copper-electrodes-dataset/resource/1c6871aa-5472"><dct:title>Modelling studies of arcs of short length between copper electrodes - Distribution of the number densities of electrons and singly charged copper ions in the discharge gap for a gap length of 3 mm (figure 5b)</dct:title><dct:description><![CDATA[<p>The figure shows the distribution of the number densitiy of electrons and singly charged copper ions for a gap length of 3 mm. The simulations is performed for a field enhancement factor of 140, a discharge radius factor of 1.2, and an initiam molar fraction of copper atoms of 0.002.<br />
Distance zero correspond to the position of the cathode.</p>
]]></dct:description><dct:issued>2025-07-15T15:27:58+02:00</dct:issued><dct:modified>2025-08-26T13:47:34+02:00</dct:modified><dcat:accessURL rdf:resource=""/><dcat:downloadURL rdf:resource="https://www.inptdat.de/system/files/node942_figure5b.csv"/><dcat:mediaType>text/csv</dcat:mediaType><dct:format>csv</dct:format><dcat:byteSize>193276</dcat:byteSize><foaf:page>https://www.inptdat.de/dataset/modelling-studies-arcs-short-length-between-copper-electrodes-dataset/resource/1c6871aa-5472</foaf:page></dcat:Distribution><foaf:Agent rdf:about="https://www.inptdat.de/publisher/n0"><foaf:name>DKAN</foaf:name><foaf:homepage>https://www.inptdat.de</foaf:homepage><dct:type rdf:resource="http://purl.org/adms/publishertype/NonProfitOrganisation"/></foaf:Agent></rdf:RDF>
