<rdf:RDF xmlns:foaf="http://xmlns.com/foaf/0.1/" xmlns:owl="http://www.w3.org/2002/07/owl#" xmlns:rdfs="http://www.w3.org/2000/01/rdf-schema#" xmlns:rdf="http://www.w3.org/1999/02/22-rdf-syntax-ns#" xmlns:dcat="http://www.w3.org/ns/dcat#" xmlns:dct="http://purl.org/dc/terms/" xmlns:adms="http://www.w3.org/ns/adms#" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:time="http://www.w3.org/2006/time#" xmlns:dcterms="http://purl.org/dc/terms/" xmlns:vcard="http://www.w3.org/2006/vcard/ns#"><dcat:Dataset rdf:about="https://www.inptdat.de/dataset/reversal-electric-field-and-anode-fall-dc-arcs-air-during-contact-opening"><dct:title>Reversal of the electric field and the anode fall in DC arcs in air during contact opening</dct:title><dct:description><![CDATA[<p>The dataset contains results of a unified one-dimensional model of an arc plasma in air, between copper electrodes, that includes the change of the gap distance. The occurance of multiple reversals of the electric field and the anode voltage drop is observed. The evolution of the spatial distribution of the electron and heavy particle temperatures with the gap distance and the opening speed is also studied. The model quantitatively predicts a number of plasma properties under conditions that are relevant to the contact separation in low-voltage switching devices.</p>
]]></dct:description><dcat:keyword>anode fall</dcat:keyword><dcat:keyword>copper electrodes</dcat:keyword><dcat:keyword>field reversal</dcat:keyword><dcat:keyword>microarc</dcat:keyword><dcat:keyword>unified description</dcat:keyword><dcat:theme>Thermal Plasma Technology</dcat:theme><dct:identifier>7fb50ba4-38ca-471d-b2d4-7b6e17ee9c04</dct:identifier><dct:issued>2024-05-24T13:14:59+02:00</dct:issued><dct:modified>2024-12-09T16:58:59+01:00</dct:modified><dct:language>en</dct:language><dct:publisher>INP</dct:publisher><dcat:distribution rdf:resource="https://www.inptdat.de/dataset/reversal-electric-field-and-anode-fall-dc-arcs-air-during-contact-opening/resource/c7de3a88"/><dcat:distribution rdf:resource="https://www.inptdat.de/dataset/reversal-electric-field-and-anode-fall-dc-arcs-air-during-contact-opening/resource/50211373"/><dcat:distribution rdf:resource="https://www.inptdat.de/dataset/reversal-electric-field-and-anode-fall-dc-arcs-air-during-contact-opening/resource/ceb352bd"/><dcat:distribution rdf:resource="https://www.inptdat.de/dataset/reversal-electric-field-and-anode-fall-dc-arcs-air-during-contact-opening/resource/eaa57c5f"/><dcat:distribution rdf:resource="https://www.inptdat.de/dataset/reversal-electric-field-and-anode-fall-dc-arcs-air-during-contact-opening/resource/49c51d81"/><dcat:distribution rdf:resource="https://www.inptdat.de/dataset/reversal-electric-field-and-anode-fall-dc-arcs-air-during-contact-opening/resource/80e0e40c"/><dcat:distribution rdf:resource="https://www.inptdat.de/dataset/reversal-electric-field-and-anode-fall-dc-arcs-air-during-contact-opening/resource/be9ece4e"/><dcat:distribution rdf:resource="https://www.inptdat.de/dataset/reversal-electric-field-and-anode-fall-dc-arcs-air-during-contact-opening/resource/3047da0e"/></dcat:Dataset><dcat:Distribution rdf:about="https://www.inptdat.de/dataset/reversal-electric-field-and-anode-fall-dc-arcs-air-during-contact-opening/resource/c7de3a88"><dct:title>Reversal of the electric field and the anode fall in DC arcs - Fig1</dct:title><dct:description><![CDATA[<p>The graph presents the curent density (in units of A/m^2) caused by thermo-field emission as a function of the surface electric field (in units of V/m) for a number of temperatures on the cathode surface (T in units of K).</p>
]]></dct:description><dct:issued>2024-06-04T15:00:10+02:00</dct:issued><dct:modified>2024-06-28T10:52:30+02:00</dct:modified><dcat:accessURL rdf:resource=""/><dcat:downloadURL rdf:resource="https://www.inptdat.de/system/files/node830_Fig1_0.csv"/><dcat:mediaType>text/csv</dcat:mediaType><dct:format>csv</dct:format><dcat:byteSize>3298</dcat:byteSize><foaf:page>https://www.inptdat.de/dataset/reversal-electric-field-and-anode-fall-dc-arcs-air-during-contact-opening/resource/c7de3a88</foaf:page></dcat:Distribution><dcat:Distribution rdf:about="https://www.inptdat.de/dataset/reversal-electric-field-and-anode-fall-dc-arcs-air-during-contact-opening/resource/50211373"><dct:title>Reversal of the electric field and the anode fall in DC arcs - Fig2-1</dct:title><dct:description><![CDATA[<p>The distribution of the electric potential in the inter-electrode gap for an opening times of 1 ms. The cathode is at position 0 mm, that of the anode varies from 0.03 mm up to 1 mm.</p>
]]></dct:description><dct:issued>2024-06-05T09:05:37+02:00</dct:issued><dct:modified>2024-06-28T10:52:30+02:00</dct:modified><dcat:accessURL rdf:resource=""/><dcat:downloadURL rdf:resource="https://www.inptdat.de/system/files/node830_Fig2_1.csv"/><dcat:mediaType>text/csv</dcat:mediaType><dct:format>csv</dct:format><dcat:byteSize>415491</dcat:byteSize><foaf:page>https://www.inptdat.de/dataset/reversal-electric-field-and-anode-fall-dc-arcs-air-during-contact-opening/resource/50211373</foaf:page></dcat:Distribution><dcat:Distribution rdf:about="https://www.inptdat.de/dataset/reversal-electric-field-and-anode-fall-dc-arcs-air-during-contact-opening/resource/ceb352bd"><dct:title>Reversal of the electric field and the anode fall in DC arcs - Fig2-2</dct:title><dct:description><![CDATA[<p>The distribution of the electric potential in the inter-electrode gap for opening times of 1 s. The cathode is at position 0 mm, that of the anode varies from 0.03 mm up to 1 mm.</p>
]]></dct:description><dct:issued>2024-06-05T09:06:40+02:00</dct:issued><dct:modified>2024-06-28T10:52:30+02:00</dct:modified><dcat:accessURL rdf:resource=""/><dcat:downloadURL rdf:resource="https://www.inptdat.de/system/files/node830_Fig2_2.csv"/><dcat:mediaType>text/csv</dcat:mediaType><dct:format>csv</dct:format><dcat:byteSize>415401</dcat:byteSize><foaf:page>https://www.inptdat.de/dataset/reversal-electric-field-and-anode-fall-dc-arcs-air-during-contact-opening/resource/ceb352bd</foaf:page></dcat:Distribution><dcat:Distribution rdf:about="https://www.inptdat.de/dataset/reversal-electric-field-and-anode-fall-dc-arcs-air-during-contact-opening/resource/eaa57c5f"><dct:title>Reversal of the electric field and the anode fall in DC arcs - Fig2-3</dct:title><dct:description><![CDATA[<p>The distribution of the electric potential in the inter-electrode gap for step-wise contact opening. The cathode is at position 0 mm, that of the anode varies from 0.03 mm up to 1 mm.</p>
]]></dct:description><dct:issued>2024-06-05T09:08:23+02:00</dct:issued><dct:modified>2024-06-28T10:52:30+02:00</dct:modified><dcat:accessURL rdf:resource=""/><dcat:downloadURL rdf:resource="https://www.inptdat.de/system/files/node830_Fig2_3.csv"/><dcat:mediaType>text/csv</dcat:mediaType><dct:format>csv</dct:format><dcat:byteSize>1339393</dcat:byteSize><foaf:page>https://www.inptdat.de/dataset/reversal-electric-field-and-anode-fall-dc-arcs-air-during-contact-opening/resource/eaa57c5f</foaf:page></dcat:Distribution><dcat:Distribution rdf:about="https://www.inptdat.de/dataset/reversal-electric-field-and-anode-fall-dc-arcs-air-during-contact-opening/resource/49c51d81"><dct:title>Reversal of the electric field and the anode fall in DC arcs - Fig3</dct:title><dct:description><![CDATA[<p>The distribution of the electric field magnitude in the inter-electrode gap for an opening time of 1 ms. The anode is at positions from 0.2 mm up to 1 mm.</p>
]]></dct:description><dct:issued>2024-06-05T09:09:20+02:00</dct:issued><dct:modified>2024-06-28T10:52:30+02:00</dct:modified><dcat:accessURL rdf:resource=""/><dcat:downloadURL rdf:resource="https://www.inptdat.de/system/files/node830_Fig3.csv"/><dcat:mediaType>text/csv</dcat:mediaType><dct:format>csv</dct:format><dcat:byteSize>188739</dcat:byteSize><foaf:page>https://www.inptdat.de/dataset/reversal-electric-field-and-anode-fall-dc-arcs-air-during-contact-opening/resource/49c51d81</foaf:page></dcat:Distribution><dcat:Distribution rdf:about="https://www.inptdat.de/dataset/reversal-electric-field-and-anode-fall-dc-arcs-air-during-contact-opening/resource/80e0e40c"><dct:title>Reversal of the electric field and the anode fall in DC arcs - Fig4a</dct:title><dct:description><![CDATA[<p>The distribution of the electron temperature in the interelectrode gap for various gap lengths..</p>
]]></dct:description><dct:issued>2024-06-05T09:10:42+02:00</dct:issued><dct:modified>2024-06-28T10:52:30+02:00</dct:modified><dcat:accessURL rdf:resource=""/><dcat:downloadURL rdf:resource="https://www.inptdat.de/system/files/node830_Fig4a.csv"/><dcat:mediaType>text/csv</dcat:mediaType><dct:format>csv</dct:format><dcat:byteSize>188997</dcat:byteSize><foaf:page>https://www.inptdat.de/dataset/reversal-electric-field-and-anode-fall-dc-arcs-air-during-contact-opening/resource/80e0e40c</foaf:page></dcat:Distribution><dcat:Distribution rdf:about="https://www.inptdat.de/dataset/reversal-electric-field-and-anode-fall-dc-arcs-air-during-contact-opening/resource/be9ece4e"><dct:title>Reversal of the electric field and the anode fall in DC arcs - Fig4b</dct:title><dct:description><![CDATA[<p>The distribution of the gas temperature in the interelectrode gap for various gap lengths.</p>
]]></dct:description><dct:issued>2024-06-05T09:11:25+02:00</dct:issued><dct:modified>2024-06-28T10:52:30+02:00</dct:modified><dcat:accessURL rdf:resource=""/><dcat:downloadURL rdf:resource="https://www.inptdat.de/system/files/node830_Fig4b.csv"/><dcat:mediaType>text/csv</dcat:mediaType><dct:format>csv</dct:format><dcat:byteSize>189695</dcat:byteSize><foaf:page>https://www.inptdat.de/dataset/reversal-electric-field-and-anode-fall-dc-arcs-air-during-contact-opening/resource/be9ece4e</foaf:page></dcat:Distribution><dcat:Distribution rdf:about="https://www.inptdat.de/dataset/reversal-electric-field-and-anode-fall-dc-arcs-air-during-contact-opening/resource/3047da0e"><dct:title>Reversal of the electric field and the anode fall in DC arcs - Fig5</dct:title><dct:description><![CDATA[<p>The total ionization rate in the interelectrode gap for various gap lengths..</p>
]]></dct:description><dct:issued>2024-06-05T09:12:46+02:00</dct:issued><dct:modified>2024-06-28T10:52:30+02:00</dct:modified><dcat:accessURL rdf:resource=""/><dcat:downloadURL rdf:resource="https://www.inptdat.de/system/files/node830_Fig5.csv"/><dcat:mediaType>text/csv</dcat:mediaType><dct:format>csv</dct:format><dcat:byteSize>189599</dcat:byteSize><foaf:page>https://www.inptdat.de/dataset/reversal-electric-field-and-anode-fall-dc-arcs-air-during-contact-opening/resource/3047da0e</foaf:page></dcat:Distribution><foaf:Agent rdf:about="https://www.inptdat.de/publisher/n0"><foaf:name>DKAN</foaf:name><foaf:homepage>https://www.inptdat.de</foaf:homepage><dct:type rdf:resource="http://purl.org/adms/publishertype/NonProfitOrganisation"/></foaf:Agent></rdf:RDF>