Precision spectroscopy of non-thermal molecular plasmas using mid-infrared optical frequency comb Fourier transform spectroscopy
| Field | Value |
|---|---|
| Group | |
| Authors | |
| Release Date | 2024-07-15 |
| Identifier | 97aea672-436e-44e7-a86f-e95a99f3bf28 |
| Permanent Identifier (DOI) | 10.34711/inptdat.840 |
| Permanent Identifier (URI) | https://www.inptdat.de/node/840 |
| Is supplementing | 10.1088/1361-6595/ad5df4 |
| Plasma Source Name | |
| Plasma Source Application | |
| Plasma Source Specification | |
| Plasma Source Properties | The plasma nitriding monitoring reactor (PLANIMOR) has been used for conducting the measurements. The plasma was generated in a pulsed DC discharge conditions of 1 kHz and a duty cycle of 60 %, at variable plasma powers of 26 W, 45 W, 93 W, and 130 W. |
| Plasma Medium Name | |
| Plasma Medium Properties | The measurements were conducted at a pressure of 3 mbar with N2 and H2 gases as the precursors, and in direct contact with a screen of carbon-fiber-reinforced carbon as a source of carbon. |
| Plasma Medium Procedure | The measurements were conducting at room temperature with no external heating. |
| Plasma Diagnostics Name | |
| Plasma Diagnostics Properties | An optical frequency comb (OFC)-based Fourier transform spectrometer, covering the spectral range from 2800 cm⁻¹ to 3400 cm⁻¹ with a repetition rate of frep ≈ 250 MHz was used. For high-resolution spectral measurements, the sub-nominal sampling approach was implemented, resulting in a final point spacing of 62 MHz. |
| Plasma Diagnostics Procedure | The PLANIMOR reactor had a multipass cell attached to it, making an effective pathlength of 190 cm. |
| Language | English |
| License | Creative Commons Attribution 4.0 International (CC BY 4.0) |
| Public Access Level | Public |
| Contact Name | Ibrahim Sadiek |
| Contact Email | ibrahim.sadiek@inp-greifswald.de |
Data and Resources
-
Precision spectroscopy of non-thermal molecular plasmas - Fig. 2CSV
Measured high-resolution spectra of a plasma nitrocarburizing. The x-axis is...
-
Precision spectroscopy of non-thermal molecular plasmas - Fig. 3CSV
Evaluated rotational populations used to create Boltzmann plot for the 0110...
-
Precision spectroscopy of non-thermal molecular plasmas - Fig. 4aCSV
Measured rotational populations, ni (in cm⁻³) as a function of rotational...
-
Precision spectroscopy of non-thermal molecular plasmas - Fig. 4bCSV
Rotational populations, ni in cm⁻³ of the 01¹0 state as a function of...
-
Precision spectroscopy of non-thermal molecular plasmas - Fig. 5CSV
Measured high-resolution spectra of a plasma nitrocarburizing. The x-axis is...