Evidence of the Dominant Production Mechanism of Ammonia in a Hydrogen Plasma with Parts Per Million of Nitrogen - Dataset

Absolute ground state atomic hydrogen densities were measured, by utilisation of two-photon absorption laser induced fluorescence (TALIF), in a low pressure electron cyclotron resonance plasma as a function of nitrogen admixtures - 0 to 5000 ppm. At nitrogen admixtures of 1500 ppm and higher the spectral distribution of the fluorescence changes from a single Gaussian to a double Gaussian distribution; this is due to a separate, nascent, contribution arising from the photolysis of an ammonia molecule. At nitrogen admixtures of 5000 ppm the nascent contribution becomes the dominant contribution at all investigated pressures. Thermal loading experiments were conducted by heating the chamber walls to different temperatures; this showed a decrease in the nascent contributions with increasing temperature. This data set contains the data shown in the corresponding publication in Appl. Phys. Lett. (https://doi.org/10.1063/5.0072534).

Field Value
Group
Authors
Release Date 2021-12-06
Identifier45f74f4c-22b0-477b-842e-de30f2cbaa82
Permanent Identifier (DOI) 10.34711/inptdat.517
Permanent Identifier (URI) https://www.inptdat.de/node/517
Is supplementing 10.1063/5.0072534
Plasma Source Name
Plasma Source Application
Plasma Source Specification
Plasma Source Properties

Electron cyclotron resonance (ECR) coaxial plasma source AURA-WAVE (Sairem):
- microwave frequency excitation 2.45 GHz
- applied power range 100 – 150 W
- chamber wall temperature varied in the range of 20° – 100°C
- volume of the plasma reactor about 80 l

Plasma Medium Name
Plasma Medium Properties

Hydrogen with dilution of nitrogen in the range of 0, 500, 1000, 1500, 2500 and 5000 ppm respectively. Total flow rate of 14 sccm is kept constant. Pressure was varied in the range of 3 – 7 Pa.

Plasma Diagnostics Name
Plasma Diagnostics Properties

Two-photon absorption laser induced fluorescence (TALIF) for the detection of hydrogen atoms. For this photons with a wavelength of 205 nm are created through the combination of a frequency doubled Nd:YAG pump laser (Spectra Physics, Quanta Ray), with a pulse width of 6 ns, and with a dye laser (Sirah, Precision Scan SL). The 615 nm red light from the dye laser is frequency doubled with the help of a BBO crystal, and then remixed with residual red light from the dye laser in a second BBO crystal for sum-frequency generation to the required 205 nm radiation.

Plasma Diagnostics Procedure

For the detection of the fluorescence a Nikon lens systems was used to image a region of interest of about 10 and 2 mm in the horizontal and vertical distances respectively. As a detector a gateable ccd camera was used (Andor iStar DH734x) in combination with a spectral filter providing a bandwidth of 10 nm centered at around 656 nm for hydrogen and 825 nm for krypton respectively.
The absolute atomic hydrogen densities could be derived from the fluorescence by calibrating the appropriate fluorescence using krypton.

Language English
LicenseCreative Commons Attribution 4.0 International (CC BY 4.0)
Public Access LevelPublic
Contact Name Lang, Norbert
Contact Email lang@inp-greifswald.de

Data and Resources